✨ New Arrivals Just Dropped!Explore
LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus
HomeStore

LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus

LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus

$406.18

Original: $1,353.94

-70%
LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus

$1,353.94

$406.18

The Story

LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus

Ready to ship    Next Business Day

E-Rated fuses have time current characteristics designed to provide current limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low value fault currents. NEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse's continuous current rating; and fuses with an E-rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an rms current of 220-240% of the fuse's continuous current rating. These values establish one point on the time-current curve.

LIVE PARTS

Live parts are available for mounting "E", "R", and "PT" single, double, and triple barrel fuses. Mounting clips are available for ferrule type and clip lock style fuses. All clips are sold in pairs. Contact factory for additional live parts.

Description

LittelFuse 80E1C15.5 E-RATED MEDIUM VOLTAGE FUSE Amperage: 80E Voltage: 15.5 KV- New Surplus

Ready to ship    Next Business Day

E-Rated fuses have time current characteristics designed to provide current limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low value fault currents. NEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse's continuous current rating; and fuses with an E-rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an rms current of 220-240% of the fuse's continuous current rating. These values establish one point on the time-current curve.

LIVE PARTS

Live parts are available for mounting "E", "R", and "PT" single, double, and triple barrel fuses. Mounting clips are available for ferrule type and clip lock style fuses. All clips are sold in pairs. Contact factory for additional live parts.

You may also like

NEW
Thumbnail 1Thumbnail 2

Trystar IL-045-VDE-B-SLIM Portable Power Distribution Center - Load Tested

$13,594.00

-70%NEW
Thumbnail 1Thumbnail 2

Appleton BJ-4-5075 Bonding Jumper - New Surplus

$39.00

$11.70

-70%NEW
Thumbnail 1Thumbnail 2

Appleton BJ-1520-24 Bonding Jumper - New Surplus

$48.00

$14.40

NEW
Thumbnail 1Thumbnail 2

Appleton BJ-4-2530 Bonding Jumper - New Surplus

$61.00

NEW
Thumbnail 1Thumbnail 2

Eaton Copper TP502 - 4SQ

$146.00

NEW
Thumbnail 1

GE&S Power Distribution Centers - Reconditioned

$17,669.14

NEW
Thumbnail 1Thumbnail 2

Hubbell Kellems 07401023 Wire Deluxe Cord Grips, Straight Male, .750-.875", 1" with Mesh-New Surplus

$322.91

-70%NEW
Thumbnail 1Thumbnail 2

BoMetals 15 in. Pro-Key Stakes 100 per box - New Surplus

$204.00

$61.20

NEW
Thumbnail 1Thumbnail 2

Schneider Electric H323DS Square D-Used

$1,340.34

NEW
Thumbnail 1Thumbnail 2

Siemens 3VU1300-1NK00 Starter Motor Protector-Used

$83.56

NEW
Thumbnail 1Thumbnail 2

Eaton Corporation PKZM1-6 Motor Protective Circuit Breaker-Used

$59.00